Professional and food industry gas cooking burners: how to reduce your energy consumption

In a context where energy savings have become a priority for catering and agrifood industry professionals, optimising cooking equipment is essential. The commercial cooking gas burners, long used with a permanent pilot light or a permanent auxiliary burner, are now being redesigned to meet the challenges of energy performance and reducing energy consumption.

The pilot light or auxiliary burner in continuous operation, although practical, consumes gas even outside cooking periods. This energy wastage has a noticeable impact on the profitability and environmental footprint of professional kitchens. Fortunately, technological developments provide reliable solutions to eliminate this excess consumption without compromising safety or performance.

AEM burner designed commercial cooking gas burners tailored to current consumption, safety and reliability needs, while also respecting fitness for purpose. Thanks to technologies that are available and in some cases combined, it is now possible to significantly reduce operating costs while simultaneously lowering the environmental impact of gas appliances.

In this article, we explain why and how to reduce your gas consumption by rethinking the use of the standing pilot light, the operation of intermittent auxiliary burners, and what the best alternatives available on the market are.

Why the standing pilot light consumes a lot of energy

The standing pilot light is a small burner of 250W maximum that stays lit continuously to make it easier to ignite the main burner. If the power output exceeds 250W, it becomes an auxiliary burner. While this system was long appreciated for a quick switch to maximum heat, it has the drawback of consuming gas throughout the whole shift, even when the main burner is not being used. This unnecessary yet constant consumption averages 750 kW per year per pilot light, which directly impacts catering operating costs, knowing that a standard cooking appliance mostly contains 5 pilot lights.

Let's take the example of a central kitchen equipped with 10 burners with standing pilots. This represents on average 750 kW per year. Depending on the type of gas used, this can amount to several hundred euros. Given that the majority of commercial cooking burners are equipped with auxiliary burners with a power output exceeding 250W, consumption is much higher. This simple observation demonstrates that the permanent pilot light, in addition to being energy-intensive, is no longer suited to the requirements of reducing CO2 emissions.

Semi-professional SP100 burner with electrode and flame monitoring thermocouple mounting plate.

Alternatives for direct control of a gas burner

FV240-30 crown burner equipped with a 2-stage automatic flame control unit for a 200-litre round-bowl boiling pan.

To eliminate the indirect ignition of a burner by a permanent pilot light or an auxiliary burner, a direct flame supervision system must be installed on the burner. If the technology used is the thermocouple of a manual safety device, it is best to combine it with a piezoelectric ignition, manually operated each time the burner is started up. Even more advanced, the automatic electronic flame controller which integrates multi-spark ignition and allows the combination of control systems that reduce energy consumption. These technologies must be used appropriately while respecting the fitness for purpose. They also enable a reduction in the manufacturing costs of the gas appliance.

AEM burner integrate these alternatives into its heating equipment gas for professional catering and the food processing industry. For example, our range of automatic ignition burners without a standing pilot light, combined with control systems to optimise the rational use of energy, enabled a school kitchen to reduce its gas consumption for cooking by nearly 15 % in one year. This type of solution fits in perfectly with the constraints of trade professionals, whilst complying with current gas and electrical safety standards.

Economic and environmental benefits of optimised burners

Adopt some commercial cooking gas burners without a permanent pilot light allows a reduction in device costs and a significant decrease in energy consumption. It requires a new adaptation by the user and a change in traditional cooking habits: the burner is only lit when heating is needed. Automatic ignition and flame control technologies offer ergonomics that make operating a gas appliance easier and better mastery of the rational use of energy, by activating the burner only when necessary and for the highest performance applications, by adapting the output according to the cooking process. Result: optimised energy efficiency and a fast return on investment.

Beyond the financial aspect, these modern burners also contribute to the reduction of the carbon footprint. Less gas burned unnecessarily also means fewer CO₂ emissions released into the atmosphere. This commitment to energy efficiency is fully aligned with companies' CSR initiatives and compliance with current environmental regulations. Thus, the optimised burners offered by AEM burner They make it possible to reconcile performance, economy and fitness for purpose, whilst guaranteeing the safety and reliability essential in a professional environment. It is certain that to further reduce the environmental impact, the use of biogas or a gas and hydrogen hybrid is the available solution today, whilst perhaps waiting for 100% hydrogen operation.

How to choose an efficient professional gas cooking burner

The essential criteria to take into account

To properly choose a commercial gas cooking burner, it is essential to consider several elements:

A perfect gas burner must combine performance, fitness for purpose, safety, energy saving and durability.

FAQ & Conclusion

Frequently asked questions (FAQ)

Because it consumes gas continuously, even outside of cooking periods. By removing it, you reduce your costs and your environmental impact, and you lower the risk of malfunction.

Yes, it provides ease of use and avoids the risk of the user burning themselves during manual ignition with a lighter, for example. When using automatic flame control, this ignition function is built-in.

Only open-hearth burners feature a specific design adapted or not to the use of a standing pilot light. Otherwise, the vast majority of our gas heating equipment is equipped with a direct flame control system.

No, contrary to popular belief, the permanent pilot light, when in use, is solely the mini burner incorporating the flame supervision system.

Conclusion

The commercial cooking gas burners without a standing pilot light offer numerous advantages: reduced energy consumption, simplified manufacture of gas appliances while complying with current standards, improved usability and reduced risks for the user. Thanks to its expertise, AEM burner supports professionals in the transition towards more efficient and sustainable solutions.