Group

The atmospheric circular burner

AEM circular burners are part of the combustion head burner range consisting of at least 1 flame ring and equipped with 1 atmospheric air/gas mixer. 2 flame orientations are available:

  • Vertical flames ; power limited to 51 kW, suitable for heating small, round-bottomed vessels. For higher power, see flame-nose burners.
  • Horizontal flames ; maximum output 230 kW, suitable for heating flat-bottomed, large-capacity containers. Also available as an assembly of 3 burners arranged at 120°.

Atmospheric ring burners

HP atmospheric circular vertical flame burner

Essentially designed for liquid heating applications, AEM circular burners are so-called “induced air” or “atmospheric air” burners developing vertical inclined flames.

  • Power from 10 to 51 kW (see nozzle-mixing burners for higher capacity)
  • Flame crown diameter from 80 to 160mm

Atmospheric circular burner with horizontal flame (fh) HP

Primarily designed for liquid heating applications, AEM circular burners are so-called “induced air” or “atmospheric air” burners that produce horizontal flames.

  • Power from 10 to 200 kW
  • Diameter from 80 to 250 mm
  • Various air/gas mixer lengths possible and applications up to 600kW by assembling 3 burners at 120°
  • Horizontal flame to reduce flame impact
  • With or without a night light
  • Propane or Natural Gas (300 mbar to 1.75 bar)

3 atmospheric circular burners at 120°C

This 3-burner configuration at 120° enables liquids to be heated in large-diameter vats and allows power to be distributed for heating delicate liquids.

  • Power output from 90 to 600 kW (Hs)
  • Minimum tank diameter 1.2m
  • 3 independent or simultaneous burners
  • With pilot ignition for outputs exceeding 119 kW
  • Natural gas or propane from 250mbar to 1.75bar

High-pressure nose atmospheric circular burner

AEM offers a range of bespoke multi-flame nozzle burners capable of delivering an output of 20 to 45kW.

  • Existing range: Circular burners equipped with 5 and 10 torch tips mounted on a circular burner body
  • Cast-iron body, nose plate and venturi mixer for atmospheric operation
  • Demand-driven inlet connection
  • Burners with a maximum external diameter of 240mm
  • Supplied by all types of low-pressure gas
  • Propane G31 – 30 mbar or G31 – 37 mbar or 50 mbar
  • Butane and 1st family gas: contact us

OPTIONS

Low-pressure ring burners

2 circular burners from the TH range have been selected for heating liquids in small-capacity tanks (maximum 250l) operating on low-pressure gas and equipped with 1 gas safety valve and 1 battery-powered igniter. A stainless steel tripod is available as an option for containers ranging from 450 to 800mm in diameter.

  • 15 kW 13,000 kcal/h (15 Th) burner, 200 mm diameter, for natural gas at 20 mbar or propane at 37 mbar, for use with containers of 120 L maximum
  • 25 Th burner for 27.5 kW, diameter 240mm, for 20mbar natural gas or 37mbar propane for vessels of up to 120l maximum
  • They can run on 28mbar butane

Semi-industrial low-pressure crown burners

Semi-industrial low-pressure crown burners

Circular vertical flame burners with a tangential mixer and an integrated flame control electrode support.

  • 2 models: FV240-21 for a rated power of 21.5kW; FV240-30 for a rated power of 30kW; the FV240-40 model is currently being validated

4-crown flame burner 50 TH

AEM offers the most powerful circular vertical flame burner, featuring 4 concentric flame rings and an output of 56kW, originally developed for the distillery sector and the heating of specific liquids.

  • Vertical flames distributed over 4 concentric rings
  • Central aperture diameter 120 mm in the case of central draining of the tank to be heated
  • Combustion head comprising: 1 body + 1 flame plate + 1 pilot washer, made of cast iron. External diameter = 350mm
  • Natural gas operation 20-25 mbar, butane/propane operation 28/37 – 50/67 – 112/148 mbar

Forced draught circular burners

This range of forced-draught burners enables operation in a closed combustion chamber with efficient, rational energy use.

  • Power output from 24 to 36 kW (Hs)
  • 2 models available: Ø140mm – Ø240mm
  • Nickel-chrome plating of the combustion head
  • Natural gas or Butane/Propane from 20 to 50 mbar