Group

The blue flame bar burner for industry

AEM bar burners feature a specific design containing a more or less regular flame pattern, allowing for a linear or shaped flame distribution, classified into 4 main ranges:

  • HP/LABO burner manifold range, axial flame
  • HP/ACM torch burner range combustion air entrainment enhanced by a compressed air supply
  • HP manifold burner range / Long flames, including satellite or long axial flame burners and flame-nose burners

AHPP: atmospheric high pressure / LBPB: low-pressure blown air.

axial flame bar burners

ATHP lab-type linear bar burners

AEM lab ribbon burners are atmospheric burners with axial flames that allow linear heating of up to 3.5m. These burners are available in several diameters and can be made to the desired length; power ranges from 10 to 25 kW per linear metre.

  • Great operational flexibility
  • All-positions flame
  • Multi-shot fire possible (up to 4 parallel shots)
  • Propane or Natural Gas (100 mbar to 1.75 bar)
  • Flame rail element in steel or stainless steel

ATHP lab type tube burners

These burners are based on LABO linear burner technology and are shaped according to heating diameters or outputs that cannot be provided by our standard range of circular burners.

  • All possible geometric shapes (U-shaped, square, hexagonal, octagonal, etc.)
  • All-round flames
  • Multiple fire trails possible (up to 4 parallel trails)
  • Propane or Natural Gas (100 mbar to 1.75 bar)
  • Flame rail component in steel or stainless steel.

Auto-piloted biscuit factory bar burner

Tube burners diameter 34mm or 42mm with a flame path of 750 to 1200mm, equipped with 1 atmospheric or forced-draught air-blown mixer, operating on natural gas or propane from 30 to 500mbar.

  • From 12 to 20 kW per linear metre of flame
  • Autopilot flames
  • Flame ionisation controller safety system
  • Stainless steel or steel
  • Power modulation 1 to 3 in the best modulation

ATH AXIAL FLAME MULTI-BURNER RAIL

This multi-manifold setup allows power to be distributed over a wide area. This technology has limited power output compared to heating using multiple linear burners placed in parallel.

  • Power adjusted according to project feasibility
  • 6-element maximum rail burner
  • 1 ATHP mixer per set of flame rails
  • With pilot ignition for outputs exceeding 119 kW
  • Natural gas or propane from 250mbar to 1.5bar

ASBP linear burner rails with axial flames

The AEM blown-air axial-flame bar burner operates on distributed gas at a pressure of less than 65 mbar and features an autonomous compact AIR/GAS injection system and a steel flame element.

  • Power from 24 to 70 kW on natural gas 15-30mbar or propane 30-50mbar
  • Operates in an overpressurised combustion chamber (100 Pa max)
  • Triple fire line ramp element: Ø48mm or Ø60mm steel tube
  • Quadruple fire line ramp element: Ø60mm steel tube
  • Heating power modulation by 0-10V signal
  • Also works with 25-40mbar butane

Formed bar burners with ASBP axial flames

This shaped-ramp configuration allows power distribution over a non-linear area whose design depends solely on the project specifications.

    • Power adjusted according to project feasibility
    • feasible shape dual-tube burner
    • 1 compact AIR/GAS injection system at the start of the rail or in the centre
    • Made entirely of steel, possibly with a nickel/chrome finish
    • Natural gas 15-30mbar or butane 25-40mbar or propane from 30mbar to 50mbar

ASBP axial flame multi-rail burners

This multi-rail configuration allows power distribution over a wide area using forced-air technology.

  • Power adjusted according to project feasibility
  • 6-element maximum rail burner
  • 1 compact AIR/GAS injection system per flame rail assembly
  • Made entirely of steel, possibly with a nickel/chrome finish
  • Natural gas 15-30mbar or butane 25-40mbar or propane from 30mbar to 50mbar

Angled-flame bar burners

ATHP angled flame linear burners

The AEM profiled pilot strip burner consists of angled flame burners (90° as standard) equipped with 1 atmospheric venturi. The burners are available in 3 main ranges depending on the steel tube diameter: Ø34mm; Ø48mm; Ø60mm

  • Maximum fire line length for Ø60mm tube: 4m (15 to 30 kW / m of fire line)
  • Maximum fire line length for Ø48mm tube: 2.5m (12 to 25 kW / m of fire line)
  • Maximum fire line length for Ø34mm tube: 1.5m (10 to 22.5 kW / m of fire line)
  • Nickel-chrome plating of the handrail component (maximum length 2m)
  • Operates on natural gas and propane from 100 mbar to 2.5 bar

ATHP shaped pilot-profile burner tube

These burners are based on linear ramp technology with a profiled pilot and are designed to provide heating diameters or power outputs that cannot be achieved by our standard range of circular burners.

  • All possible geometric shapes (U-shaped, square, hexagonal, octagonal, etc.)
  • Propane or Natural Gas (300 mbar to 2.5 bar)
  • Steel or Stainless Steel Handrails

ASBP angled multi-burner rails

The AEM forced-draught angled flame burner operates on gas supplied at a pressure of less than 65 mbar and is fitted with a compact, self-contained air/gas injection system and a steel flame element.

  • Power from 24 to 70 kW on natural gas 15-30mbar or propane 30-50mbar
  • Operates in an overpressurised combustion chamber (100 Pa max)
  • Triple fire line ramp element: Ø48mm or Ø60mm steel tube
  • Heating power modulation by 0-10V signal
  • Also works with 25-40mbar butane

Atmospheric long-flame rail burner

Long flame bar burner

This ramp burner technology delivers an output of 25 to 40 kW per linear metre and utilises long flames to increase the distance between the burner and the surface to be heated.

  • Power adjusted according to project feasibility
  • Steel or stainless steel handrail section
  • 1 ATHP or ATHP/ACM (air motor mixer) blender
  • Natural gas or propane from 150mbar to 2.0bar

Atmospheric ramp burners with flame nozzles

AEM nozzle bar burners are “induced air” burners comprising a main manifold and torch burner nozzles. These burners allow linear heating up to a maximum length of 2m; power output from 40 to 70 kW per linear metre.

  • Multi-position flame
  • Propane or Natural Gas (300 mbar to 2.5 bar)
  • Ramps with steel, stainless steel or heat-resistant steel noses depending on operating temperatures
  • Supplied with an interlock burner

Bar burner

Atmospheric ramp burners with flame nozzles

A nose-shape burner makes it possible to apply a high level of power to a non-linear heating zone.

  • All possible geometric shapes (U-shaped, square, octagonal, etc.)
  • Propane or Natural Gas (300 mbar to 2.5 bar)
  • Ramps with steel or stainless steel nosings, depending on the operating temperatures
  • Supplied with an interlock burner