Low-pressure blown air burner
Range of multi-flame axial air-blown ramp burners
Heat distribution for a rectangular surface with several flame elements with a diameter of 34mm. From 4 to 6 flame elements in a staggered arrangement. Air-to-air air-fed gas supply system AEM
Range of blown-air ramp burners with flame in an angle
Power adjusted according to the gas and the length of the flame path. The flames are controlled and directed at 90° by 2 parallel flame lines.
- Operates at 230Vac
- Air-gas injection by NRG118 fan and Honeywell venturi: conversion of natural gas/propane by changing the injector and adjusting the proportion screw
- Low-pressure gas supply 70mbar max
- Max nominal power: 70 kW (Hi)

Range of blown-air ramp burners with axial flames
Power adjusted according to the gas and the length of the flame path. The flames are controlled and directed at the center of the flame support tube.
- Operates at 230Vac
- Air-gas injection by NRG118 fan and Honeywell venturi: conversion of natural gas/propane by changing the injector and adjusting the proportion screw
- Low-pressure gas supply 70mbar max
- Max nominal power: 70 kW (Hi)
Modulating air-blown burner 18 to 22 kW for the CE market
It is a circular burner with a motorized combustion air supply with a modulating power of approximately 7.5 to 22 kW.
- Natural gas usage 20mbar to 25mbar or propane 37mbar or 50mbar
- Technology of blown air burners with gas power control by the blown air flow rate
- Operation with the HONEYWELL ESYS system at 230V 50Hz
- Power variation made by a 0-10V or 4-20mA signal
- Power range determined by the dimensioning of the gas aspiration venturi and the air/gas pre-mixing system
- Flame control by a mono-electrode or two electrodes. Flame monitoring is done by ionization